- Component
- Dosing chamber
- Job
- Stores clarified effluent before each dose
- What a technician checks
- Liquid level, watertightness, solids, reserve volume, riser, and lid
- Common warning
- Rain-related high water, odor, infiltration, or corrosion
- Component
- Effluent pump
- Job
- Creates the design flow and pressure
- What a technician checks
- Model, current draw, run time, head, discharge, and physical condition
- Common warning
- No run, short cycling, overload, unusual noise, or low pressure
- Component
- Floats or timer
- Job
- Start and stop the dose and trigger high water
- What a technician checks
- Elevation, tether, freedom of movement, settings, and test cycles
- Common warning
- Stuck float, changed setting, excess cycles, or missed dose
- Component
- Control panel
- Job
- Protects, schedules, counts, and reports pump operation
- What a technician checks
- Breaker, contacts, timer, counter, run-time meter, enclosure, and labels
- Common warning
- Tripped protection, moisture, heat, fault light, or blank display
- Component
- Audible and visual alarm
- Job
- Warns before storage is exhausted
- What a technician checks
- Independent circuit, float, horn, light, label, and reset
- Common warning
- High-water light, silence, disabled horn, or repeat alarm
- Component
- Filter and check valve
- Job
- Keep solids out and control unwanted return flow
- What a technician checks
- Cleaning, seating, flow direction, leakage, and accessibility
- Common warning
- Slower dosing, cycling, uneven pressure, or backup
- Component
- Manifold, laterals, and turnups
- Job
- Divide flow across the permitted field and allow testing or flushing
- What a technician checks
- Pressure, residual head, orifices, caps, damage, roots, and flush return
- Common warning
- One wet zone, weak distal flow, broken cap, or surfacing